Dorm Receptacles

Project ID: FA480926Q0030 FederalOpportunitiesSolicitation
Overview
AgencyAir Combat Command
Deadline05/18/26
Posted05/05/26
Estimated Value$85,000 - $180,000 (AI estimate)
Set AsideSBA
NAICS238210 - Electrical Contractors and Other Wiring Installation Contractors
PSCN059 - Installation Of Equipment- Electrical And Electronic Equipment Components
LocationGoldsboro, NC 27531 United States
Description
Primary Latest Change

This requirement is for the complete turn-key installation of new electrical circuits and outlets at eight (8) Unaccompanied Military Housing (dormitory) buildings at Seymour Johnson Air Force Base (SJAFB), North Carolina. The service will provide dedicated, accessible power to the ground-floor stairwells (East and West ends) of each facility. The scope requires the contractor to furnish all labor, materials, and equipment to install sixteen (16) new 20-amp, 120-volt Ground Fault Circuit Interrupter (GFCI) circuits. These circuits will power a total of sixty-four (64) new 15-amp duplex receptacles, with four receptacles per stairwell. Key materials include approximately 2,900 linear feet of 3/4" Schedule 40 PVC conduit, over 8,600 feet of #12 THWN-THHN copper wire, GFCI-compatible weatherproof "in-use" covers, and 20-amp single-pole, bolt-on GFCI circuit breakers compatible with the existing Siemens electrical panels. All work, materials, and labeling shall conform to the most current editions of the National Electrical Code (NEC), UFC 3-501-01, and UFC 3-520-01. Please review site visit information in Instructions, Conditions, & Notices to Offerors or Quoters section of attached Solicitation FA480926Q0030.

Summary (Newest Update)

Background This requirement is for the complete turn-key installation of new electrical circuits and outlets at eight (8) Unaccompanied Military Housing (dormitory) buildings at Seymour Johnson Air Force Base (SJAFB), North Carolina. The service aims to provide dedicated, accessible power to the ground-floor stairwells (East and West ends) of each facility. The project is initiated due to a determination that additional electrical receptacles are necessary for safety and accessibility. Work Details The contractor will furnish all labor, materials, and equipment necessary to install sixteen (16) new 20-amp, 120-volt Ground Fault Circuit Interrupter (GFCI) circuits. These circuits will power a total of sixty-four (64) new 15-amp duplex receptacles, with four receptacles per stairwell in each of the eight dormitory buildings: 3613, 3614, 3615, 3616, 3603, 3605, 3606, and 3607. Key materials include approximately 2,900 linear feet of 3/4" Schedule 40 PVC conduit, over 8,600 feet of #12 THWN-THHN copper wire, GFCI-compatible weatherproof 'in-use' covers, and 20-amp single-pole bolt-on GFCI circuit breakers compatible with existing Siemens electrical panels. All work must conform to the latest editions of the National Electrical Code (NEC), UFC 3-501-01, and UFC 3-520-01. The contractor is responsible for routing a new dedicated circuit from the electrical panel to each stairwell while ensuring all installations are cleanly executed and professionally labeled. Period of Performance The contract will be performed over a period of approximately 90 calendar days from the date of award. Place of Performance The construction projects will be performed at Seymour Johnson Air Force Base in North Carolina.

Contacts
Contact nameDEANDRE FULLER
Contact emaildeandre.fuller@us.af.mil
Contact phone(919) 722-1588
Secondary contact nameMichael J Demers
Secondary contact emailmichael.demers.1@us.af.mil
Secondary contact phone(919) 722-1599
Same Region Opportunities