Sawyer Creek Culvert

Project ID: W911S226U3442 FederalOpportunitiesSynopsis Solicitation
Overview
AgencyMICC Fort Drum
Deadline06/22/26
Posted06/16/26
Estimated Value$45,000 - $95,000 (AI estimate)
Set AsideSBA
NAICS331210 - Iron and Steel Pipe and Tube Manufacturing from Purchased Steel
PSC5450 - Miscellaneous Prefabricated Structures
LocationT-84 1st St West Fort Drum, NY 13602 Fort Drum, NY 13602 USA
Description
Primary Latest Change

5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections). Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering.

Summary (Newest Update)

Background The solicitation is issued by the U.S. Army for the procurement of a box culvert as part of infrastructure development. The goal is to provide a durable and structurally sound culvert that meets specific engineering standards and requirements, ensuring compliance with federal regulations and safety standards. Work Details The contract involves the delivery of a 5' wide x 6' high x 51.7' length box culvert, which includes: - Approximately 51.7 lineal feet of 5' (span) x 6' (rise) I.D. of box culvert (8 sections). - Cutoff walls for (2) culvert ends and (4) wingwalls. - (4) L-shaped cantilever wingwalls, each 8' long. - (2) headwalls, one at each end measuring 1' wide x 1' high on each end section. - Neoprene gaskets installed on each box section prior to delivery. - Exterior waterproofing by others. - Level 1 black bar reinforcing carried with HL-93 live load rating assumed (New York PE stamp with supporting calculations provided). - Class 100 tracked and Class 120 wheeled in accordance with UFC 3-310-08 specifications. - The skew angle of the culvert with the road will be 24 degrees. - Drawings/submittals must be stamped by a PE licensed in NY with supporting engineering documentation. Period of Performance The geographic location(s) the product will be delivered to or performed at. Place of Performance Delivery is to be made to a specified location as indicated in the solicitation documents. Bidder Requirements This is a Total Small Business Set Aside (SBA). Bidders must provide new equipment only; used or remanufactured products will not be accepted. Bidders must meet all salient characteristics specified in the solicitation and provide appropriate documentation to demonstrate compliance. Incumbent Analysis (see Incumbents section for more detail) This opportunity for a 5' x 6' x 51.7' box culvert with associated cutoff walls, wingwalls, headwalls, neoprene gaskets, and HL-93/Class 100/120 load rating requirements appears to align with prior Army “S2P2: CULVERTS” awards under the same procurement vehicle. Closely related prior contracts include W911S225PA934 awarded to Burhani Enterprises ($87,734) and W911S225PB212 awarded to Technologisty ($23,695), both described as culverts solicitations, suggesting similar box culvert scope and engineering/submittal requirements. Additional related work includes W911S226PA206 awarded to Aantilia ($4,840) for an S2P2 “CULVERT SOLICITATION,” indicating continuity in culvert fabrication/delivery requirements.

Contacts
Contact nameCarrie Lawton
Contact emailcarrie.l.lawton.civ@army.mil
Contact phone7721065
Same Region Opportunities

Camera and Lens

Agency: Nassau County Procurement [NY]

Location: New York

NAICS: Not Provided