Facility Grounds Maintenance Services
Agency: Eastern State Hospital [VA]
Location: Virginia
NAICS: Not Provided
| Agency | Maritime Administration |
|---|---|
| Deadline | 06/01/26 |
| Posted | 05/29/26 |
| Estimated Value | Not Provided |
| Set Aside | SBA |
| NAICS | 336611 - Ship Building and Repairing |
| PSC | 2090 - Miscellaneous Ship And Marine Equipment |
| Location | Fort Eustis, VA 23604 United States |
This is a combined synopsis/solicitation for commercial products and/or commercial services prepared in accordance with Revolutionary FAR Overhaul (RFO) Part 12 Acquisition of Commercial Products and Commercial Services. This announcement constitutes the only solicitation. Offers are being requested, and a separate written solicitation will not be issued. The U.S. Department of Transportation (DOT), Maritime Administration (MARAD), James River Reserve Fleet (JRRF) is seeking to solicit a dehumidification system. Issuance of a firm-fixed price purchase order is anticipated for service and material to perform this work in accordance with specifications in the Statement of Work (SOW). Quoters are to submit pricing for all materials to deliver on the vendor price sheet.
Background The U.S. Department of Transportation (DOT), Maritime Administration (MARAD), James River Reserve Fleet (JRRF) is seeking to procure a dehumidification system. This solicitation is part of the Revolutionary Overhaul (RFO) Part 12 Acquisition of Commercial Products and Commercial Services, aiming to issue a firm-fixed price purchase order for the necessary service and materials as specified in the Statement of Work (SOW). Work Details The contractor shall provide one (1) Munters Model HCD-600-EA-SFS High-Capacity Desiccant Dehumidification System, which must utilize a HoneyCombe® desiccant wheel and be configured with Electric Activation (EA). The salient characteristics include: - Dimensions & Configuration: Must utilize the SFS (Small Frame System) configuration for specific shipboard installation. - Performance: Nominal process airflow of 600 SCFM with a moisture removal capacity of at least 16 lbs/hr at standard inlet conditions (75°F / 50% RH). - Construction: Marine-grade, corrosion-resistant aluminum cabinet with a NEMA 4 rated control enclosure. - Integration: Must be compatible with existing PLC monitoring protocols currently utilized by the fleet. Specifications include: - Manufacturer/Model: Munters Model HCD-600-EA-SFS (or approved equal meeting all specs) - Technology Type: Desiccant Rotor (Active self-regenerating) - Process Air Flow: Nominal 600 SCFM - Moisture Removal: Minimum 16 lbs/hr (at 75°F / 50% RH) - Reactivation Type: Electric (EA) with solid-state proportioning control - Enclosure: All-welded, strain-hardened Aluminum for marine environments - Control System: NEMA 4 rated enclosure with PLC-based logic and HMI interface - Electrical: Specify your site voltage, e.g., 460V / 3 Phase / 60Hz - Filtration: MERV 8 pre-filter (Process) and Metal Mesh (Reactivation). Additionally, a 5-Year Comprehensive Spare Parts Kit tailored for the HCD-600-EA-SFS must be included, containing replacement drive belts, seals, motors, heaters, and filtration media sufficient for five years of continuous operation. Place of Performance James River Reserve Fleet
| Contact name | Mr. Cory Lynch |
|---|---|
| Contact email | cory.lynch@dot.gov |
| Contact phone | (757) 322-5822 |
Agency: Eastern State Hospital [VA]
Location: Virginia
NAICS: Not Provided
Agency: Culpeper County Government [VA]
Location: Virginia
NAICS: Not Provided
Agency: Air Combat Command
Location: Virginia
NAICS: 314110
Agency: MSC Headquarters
Location: Virginia
NAICS: 332911