SPE8E326R0001 amendment 0002
Agency: DLA Troop Support - Construction and Equipment
Location: Pennsylvania
NAICS: 33999
| Agency | VISN 4 |
|---|---|
| Deadline | 06/02/26 |
| Posted | 05/26/26 |
| Estimated Value | $180,000 - $350,000 (AI estimate) |
| Set Aside | None |
| NAICS | 339113 - Surgical Appliance and Supplies Manufacturing |
| PSC | 6530 - Hospital Furniture, Equipment, Utensils, And Supplies |
| Location | Pittsburgh VA Medical Center Pittsburgh, PA 15240 United States |
SOURCES SOUGHT NOTICE THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION (RFI) ONLY. This RFI is issued solely for information and planning purposes and shall not be construed as a solicitation or obligation on the part of the Department of Veterans Affairs. No solicitation exists at this time; therefore, no request for a solicitation will be answered. The Department of Veterans Affairs (VA), Veterans Affairs Pittsburgh Healthcare System (VAPHS), is conducting market research to identify qualified and capable sources (SDVOSB, VOSB, Small Business, and Large Business) that can provide a brand name or equivalent Distribution Systems International, Inc. (DSI) Modumax/Moducore - Custom Supply Storage System that meets the salient characteristics and performance requirements listed below. VA Pittsburgh Healthcare System (VAPHS) SCOPE OF WORK AND GENERAL DESCRIPTION Distribution Systems International, Inc. (DSI) Modumax/Moducore - Custom Supply Storage System Introduction Pittsburgh s supply room for the Operating Room will be moving locations, and the complete conversion from current wire track shelving to a Custom High Density Basket System. This will consolidate all Operating Room supply inventory into the Center Core for proper storage. The contractor shall complete turnkey installation and assembly. The contractor shall coordinate delivery, unload, and stage equipment upon arrival. The contractor shall provide training and demonstration of the systems used by VA employees. This requirement is currently aligned to the (DSI) Modumax/Moducore - Custom Supply Storage System, or brand name equivalent capable of meeting all salient characteristics detailed in this notice. Specifications / Salient Characteristics Brand Name or Equal to DSI Modumax/Moducore: Reference Number Description Quantity KIT-D1-MM-CUSTOM-A.ST ModuCore Single Tier A-ST 18.9375 W : Custom (9) basket/shelf configuration 49 Ea KIT-D1-MM-CUSTOM-A.AD ModuCore Single Tier A-AD 17.625 W : Custom (9) basket/shelf configuration 101 Ea KIT-D1-MM-CUSTOM-A.SUT ModuCore Single Tier A-SUT 17.625 W : Custom (7) basket/shelf configuration (suture) 6 Ea KIT-D1-MM-CUSTOM-B.ST ModuCore Single Tier B-ST 26.875 W : Custom (9) basket/shelf configuration 4 Ea KIT-D1-MM-CUSTOM-WA.ST ModuCore Single Tier WA-ST 38.25 W : Custom (7) basket/shelf configuration 4 Ea KIT-D1-CUSTOM-COLORPANEL-FULL/A Custom Color Panel for Side of ModuMax A Unit Color and Phrase Chosen After Initial Install 25 Ea KIT-D1-CUSTOM-COLORPANEL-FULL/B Custom Color Panel for Side of ModuMax B Unit Color and Phrase Chosen After Initial Install 2 Ea KIT-D1-CUSTOM-COLORLABEL/A Custom Color Panel for Top of All ModuMax Units Color and Phrase Chosen After Initial Install 164 Ea KIT-D1-CUSTOM-HANDLE/BSK-2A 2 ModuCore A Basket Handle Fits All Baskets and Trays 1200 Ea KIT-D1-ITEM No Hassle DSI Lifetime Warranty Included 1 Ea KIT-D1-ITEM DSI Complemntrary HSPA Compliance Vendor Partner Site Assessment Included 1 Ea KIT-D1-INSTALLATION Complete Onsite Assembly and Installation 1 Ea Salient Characteristics: The required storage system must meet the following minimum essential physical, functional, and performance characteristics to support safe, efficient, and compliant Operating Room (OR) operations: System Configuration & Compatibility Modular storage system designed specifically for perioperative and procedural supply management. Fully compatible with Operating Room clean central core, sub sterile, and supply room workflows. Must integrate with existing VAPHS storage layouts without structural modification. Construction & Materials Frame and shelving constructed of medical grade, corrosion resistant steel or anodized aluminum suitable for high humidity and high turnover Operating Room settings. All components must withstand frequent cleaning with VA approved disinfectants. Smooth, non porous surfaces that comply with infection prevention standards. Shelving & Storage Functionality Adjustable modular shelving that supports customizable bin/supply arrangements. Weight capacity is sufficient for heavy Operating Room supply loads (implant trays, sterile instrument sets, etc.). Shelves must allow airflow to support sterile storage requirements. Optional accessories (dividers, bins, labeling rails) must be compatible with the system. Mobility & Stability Mobile units must include medical grade locking casters that provide stability during use. Carts must maneuver safely in Operating Room corridors and storage areas without tipping. Dimensional Requirements: Units must fit within the existing Operating Room core footprint, including doorways, alcoves, and designated storage zones (blueprint attachment). Height must permit safe access by nursing and sterile processing personnel. System Dimensions (custom system shall be built): Height must be between 73 (inches) and 73.25 (inches). Width must be between 18.5 (inches) and 19 (inches). Depth must be between 25 (inches) and 25.5 (inches). Must have aluminum frames with 1.5 x 1.5 diameter. Must have 1 (inch) vertical basket/tray adjustability. Supply Room Dimensions: Separate attachment OR Clean Core Dimensions . Infection Control & Cleanability Surfaces must be able to withstand daily disinfection per VHA guidelines. No seams, gaps, or exposed hardware that could harbor bioburden. System must support clean/sterile supply segregation. Safety & Ergonomics Design must support safe material handling, reducing staff strain and injury risk. Pull out components must have safety stops to prevent tipping or accidental release. Durability & Longevity Minimum expected service life: 10 years under continuous Operating Room usage. Manufacturer must provide warranty and maintenance support consistent with industry standards. Assembly & Installation Must be installed without structural modification to walls, floors, or Operating Room infrastructure. The Contractor must provide on site installation, configuration, and system testing. System must be fully operational upon implementation. Documentation & Support The Contractor must supply assembly instructions, maintenance recommendations, and replacement part lists. Availability of replacement parts must be guaranteed for the life of the product. Contractor must provide staff orientation/training on system use and configuration. Delivery Location Delivery and Installation of all materials to: Pittsburgh VAMC Attn: Operating Room University Drive C. Pittsburgh, PA 15240 Deliverables Fully installed and operational custom supply storage system. Contractor shall complete on-site installation within designated timeframe. Contractor shall provide basic training system for VA Pittsburgh staff. Training: Contractor shall provide a one-day on-site instructor-led session of user training upon VA staff request. Contractor shall provide a detailed user manual, along with customer support for follow-up training if required. REQUEST FOR INFORMATION VENDOR RESPONSE QUESTIONS Business size/status under applicable NAICS code. Is the equipment on a Federal Supply Schedule or GWAC? Include schedule number. Are you the manufacturer or distributor? If not, address the Non-Manufacturer Rule. If a large business, identify authorized small business distributors. If a small business reseller, describe any modifications made to items. Is the item manufactured in the United States? If subcontracting, list percentage breakdown of subcontracted vs. self-performed work. Provide general market pricing for research purposes only. Provide capability statement addressing salient characteristics. Review the SOW and provide feedback or N/A. Provide your UEI number. Submission Instructions Responses must be sent to Olivia McDonald at olivia.mcdonald@va.gov no later than 4:00 PM EST on 06/02/2026. DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. Responses are not offers and cannot be accepted to form a binding contract.
Background The Department of Veterans Affairs (VA), Veterans Affairs Pittsburgh Healthcare System (VAPHS), is conducting market research to identify qualified and capable sources that can provide a brand name or equivalent Distribution Systems International, Inc. (DSI) Modumax/Moducore - Custom Supply Storage System. This initiative is part of the VA's effort to enhance the efficiency and safety of Operating Room operations by transitioning from wire track shelving to a custom high-density basket system for better inventory management. Work Details The contractor shall provide a complete turnkey installation and assembly of the DSI Modumax/Moducore Custom Supply Storage System, which includes the following items: - KIT-D1-MM-CUSTOM-A.ST: ModuCore Single Tier A-ST (18.9375" W, 9 basket/shelf configuration) - 49 Ea - KIT-D1-MM-CUSTOM-A.AD: ModuCore Single Tier A-AD (17.625" W, 9 basket/shelf configuration) - 101 Ea - KIT-D1-MM-CUSTOM-A.SUT: ModuCore Single Tier A-SUT (17.625" W, 7 basket/shelf configuration for suture) - 6 Ea - KIT-D1-MM-CUSTOM-B.ST: ModuCore Single Tier B-ST (26.875" W, 9 basket/shelf configuration) - 4 Ea - KIT-D1-MM-CUSTOM-WA.ST: ModuCore Single Tier WA-ST (38.25" W, 7 basket/shelf configuration) - 4 Ea - KIT-D1-CUSTOM-COLORPANEL-FULL/A: Custom Color Panel for Side of ModuMax A Unit - 25 Ea - KIT-D1-CUSTOM-COLORPANEL-FULL/B: Custom Color Panel for Side of ModuMax B Unit - 2 Ea - KIT-D1-CUSTOM-COLORLABEL/A: Custom Color Panel for Top of All ModuMax Units - 164 Ea - KIT-D1-CUSTOM-HANDLE/BSK-2A: ModuCore A Basket Handle - 1200 Ea - Additional items include warranty and installation services. Place of Performance Delivery and installation will take place at the Pittsburgh VA Medical Center, University Drive C., Pittsburgh, PA 15240. Bidder Requirements Bidders must be able to provide a brand name or equivalent product that meets all salient characteristics outlined in the notice. They should also indicate their business size/status and confirm if they are the manufacturer or distributor. If subcontracting is involved, bidders must provide a breakdown of subcontracted versus self-performed work. Incumbent Analysis (see Incumbents section for more detail) The prior contract 36C24426P0006 was awarded to Apex Integrated Distribution for $51,051 (10/23/25–11/14/25) for DSI Modumax high-density shelving. The current requirement is also for a DSI Modumax/Moducore custom high-density basket storage system with turnkey delivery, installation, assembly, and training at the Pittsburgh VA Medical Center, indicating the earlier work likely involved the same type of storage system and installation approach as a continuation or expansion of that shelving conversion.
| Contact name | Olivia McDonald |
|---|---|
| Contact email | olivia.mcdonald@va.gov |
| Contact phone | (412) 860-7204 |
Agency: DLA Troop Support - Construction and Equipment
Location: Pennsylvania
NAICS: 33999
Agency: DLA Distribution
Location: Pennsylvania
NAICS: 236220
Agency: USACE Baltimore District
Location: Pennsylvania
NAICS: 237310
Agency: NSWC Philadelphia Division
Location: Pennsylvania
NAICS: 336611