Qty 1 Patterson-Kelley Model PK-08D Semi-Instantaneous Water Heater rated to provide 27 GPM of Domestic Hot Water from 40-120F when supplied with 25 psig Inlet Steam and 5 psig in the Coil @ 1122#/hr. Heater to be furnished with the following features and controls to meet the specified demand: - Solid Copper Nickel Pressure Vessel rated for 150 psi ASME working pressure. - Factory Insulation. - 90/10 Double Wall Copper Nickel Tube Bundle rated for 150 psi ASME working pressure and 210F test pressure. - All bronze circulator pump, 1/6HP, NYC Trim Package, 115v/1ph/60Hz, with isolation valves, ball and check valves, and venturi tees. - 1 1 2 Spence Pilot Operated, Self-Contained Steam Control Valve. - 1 1 2 Wye Strainer. - 3 4 ASME Temperature & Pressure Relief Valve at 150 psi. - 3 4 ASME Pressure Only Relief Valve (Shipped Loose). - 1 1 2 Float & Thermostatic Condensate Steam Trap & Strainer (Shipped Loose). - 1 2 Auxiliary Drip Tap (Shipped Loose). - 3 4 Drain Valve Factory Installed. - Double Solenoid High Temperature Limit System with pre-wired control box. - Vertical Stand suitable for removal of heating section without disconnection of domestic water lines. - 3 4 Vacuum Breaker Factory Installed. - 3 1 2 Dial Thermometer & Bundle Steam Pressure Gauge. - Operation & Maintenance Manuals in electronic form. - Factory Authorized Start-Up & Training Tags: 276458 (WH-2) Qty 1 Patterson-Kelley Model PK-10D Semi-Instantaneous Water Heater rated to provide 65 GPM of Domestic Hot Water from 40-140F when supplied with 40 psig Inlet Steam and 25 psig in the Coil @ 3469#/hr. Heater to be furnished with the following features and controls to meet the specified demand: - Solid Copper Nickel Pressure Vessel rated for 150 psi ASME working pressure. - Factory Insulation. - 90/10 Double Wall Copper Nickel Tube Bundle rated for 150 psi ASME working pressure and 210F test pressure. - All bronze circulator pump, 1/6HP, NYC Trim Package, 115v/1ph/60Hz, with isolation valves, ball and check valves, and venturi tees. - 2 1 2 Spence Pilot Operated, Self-Contained Steam Control Valve. - 2 1 2 Wye Strainer. - 1 ASME Temperature & Pressure Relief Valve at 150 psi. - 1 1 2 ASME Pressure Only Relief Valve (Shipped Loose). - 1 1 2 Float & Thermostatic Condensate Steam Trap & Strainer (Shipped Loose). - 1 2 Auxiliary Drip Tap (Shipped Loose). - 3 4 Drain Valve Factory Installed. - Double Solenoid High Temperature Limit System with pre-wired control box. - Vertical Stand suitable for removal of heating section without disconnection of domestic water lines. - 3 4 Vacuum Breaker Factory Installed. - 3 1 2 Dial Thermometer & Bundle Steam Pressure Gauge .
Background The Department of Veterans Affairs is issuing a solicitation for the replacement of water heaters at the Lyons VAMC. The goal is to ensure compatibility with existing hookups without requiring additional piping. This contract is critical for maintaining efficient domestic hot water supply in the facility. Work Details The contract includes the procurement of two Patterson-Kelley Semi-Instantaneous Water Heaters: 1. **Patterson-Kelley Model PK-08D** - Rated to provide 27 GPM of Domestic Hot Water from 40-120F when supplied with 25 psig Inlet Steam and 5 psig in the Coil @ 1122#/hr. - Features include: - Solid Copper Nickel Pressure Vessel rated for 150 psi ASME working pressure. - Factory Insulation. - 90/10 Double Wall Copper Nickel Tube Bundle rated for 150 psi ASME working pressure and 210F test pressure. - All bronze circulator pump, 1/6HP, NYC Trim Package, 115v/1ph/60Hz, with isolation valves, ball and check valves, and venturi tees. - 1 ½” Spence Pilot Operated, Self-Contained Steam Control Valve. - 1 ½” Wye Strainer. - ¾” ASME Temperature & Pressure Relief Valve at 150 psi. - ¾” ASME Pressure Only Relief Valve (Shipped Loose). - 1 ½” Float & Thermostatic Condensate Steam Trap & Strainer (Shipped Loose). - ½” Auxiliary Drip Tap (Shipped Loose). - ¾” Drain Valve Factory Installed. - Double Solenoid High Temperature Limit System with pre-wired control box. - Vertical Stand suitable for removal of heating section without disconnection of domestic water lines. - ¾” Vacuum Breaker Factory Installed. - 3 ½” Dial Thermometer & Bundle Steam Pressure Gauge. - Operation & Maintenance Manuals in electronic form. - Factory Authorized Start-Up & Training. 2. **Patterson-Kelley Model PK-10D** - Rated to provide 65 GPM of Domestic Hot Water from 40-140F when supplied with 40 psig Inlet Steam and 25 psig in the Coil @ 3469#/hr. - Features include: - Solid Copper Nickel Pressure Vessel rated for 150 psi ASME working pressure. - Factory Insulation. - 90/10 Double Wall Copper Nickel Tube Bundle rated for 150 psi ASME working pressure and 210F test pressure. - All bronze circulator pump, 1/6HP, NYC Trim Package, 115v/1ph/60Hz, with isolation valves, ball and check valves, and venturi tees. - 2 ½” Spence Pilot Operated, Self-Contained Steam Control Valve. - 2 ½” Wye Strainer. - 1” ASME Temperature & Pressure Relief Valve at 150 psi. - 1 ½” ASME Pressure Only Relief Valve (Shipped Loose). - Float & Thermostatic Condensate Steam Trap & Strainer (Shipped Loose). - Auxiliary Drip Tap (Shipped Loose). - Drain Valve Factory Installed. - Double Solenoid High Temperature Limit System with pre-wired control box. - Vertical Stand suitable for removal of heating section without disconnection of domestic water lines. - Vacuum Breaker Factory Installed. - Dial Thermometer & Bundle Steam Pressure Gauge. Place of Performance Lyons VAMC, located at 151 Knollcroft Road, Lyons NJ, USA.
| Contact name | Corey Swinton |
|---|---|
| Contact email | corey.swinton@va.gov |
| Contact phone | None |
Agency: South Orange-Maplewood School District [NJ]
Location: New Jersey
NAICS: Not Provided
Agency: Ocean County Buildings and Grounds, Bridges, Corrections, Engineering, Fire/First Aid Training Center, Juvenile Services, Parks, Roads [NJ]
Location: New Jersey
NAICS: Not Provided
Agency: Buildings and Grounds, Vehicle Services, Printing and Graphics [NJ]
Location: New Jersey
NAICS: Not Provided
Agency: Ocean County Corrections; Juvenile Services [NJ]
Location: New Jersey
NAICS: Not Provided