Primary Latest Change

Summary

The Pawnee Indian Health Center (PIHC), Indian Health Services (IHS) has a need for monitors to be able to monitor patient vital signs. For patient safety, the provider needs to be able to monitor vital signs during patient visits and select procedures. This will allow the medical clinic to continue to provide comprehensive daily services for Native American and Alaskan Natives of the PIHC. 2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS The contractor shall provide the following for the Pawnee Indian Health Center Medical Department: 1. (7) 74CT-B Connex Spot Monitor OR equal Includes: Sure BP NIBP, Temperature, SpO2 Pulse Rate and SpO2. Voltage: 120 volts

Color Touchscreen Interface

NIBP o Inflation range: Adult/Pediatric: 0 to 300 mmHg; Neonate: 0 to 150 mmHg

BP Determination Time

15 Seconds typical, 150 Seconds Max o Complies with ANSI/AAMI SP-10:2002 and ISO/ANSI/AAMI 81060-2:2013 standards

Pulse Oximetry

o Range: 1 to 100%

Pulse Rate Range

25-240Bpm 2. (7) Mobile Work Surface

Summary (Newest Update)

Background The Pawnee Indian Health Center (PIHC), part of the Indian Health Services (IHS), aims to enhance patient safety by acquiring vital sign monitors. This initiative is crucial for monitoring patient vital signs during visits and procedures, ensuring the clinic can continue providing comprehensive services to Native American and Alaskan Natives. Work Details The contractor shall provide the following for the Pawnee Indian Health Center Medical Department: 1. (7) 74CT-B Connex Spot Monitor or equal: - Includes: Sure BP NIBP, Temperature, SpO2 Pulse Rate and SpO2. - Voltage: 120 volts - Tabular and Graphical Display - Audible and Visual Alarm - Color Touchscreen Interface - NIBP: - Inflation range: Adult/Pediatric: 0 to 300 mmHg; Neonate: 0 to 150 mmHg - BP Determination Time: 15 Seconds typical, 150 Seconds Max - Complies with ANSI/AAMI SP-10:2002 and ISO/ANSI/AAMI 81060-2:2013 standards - Pulse Oximetry: - Range: 1 to 100% - Pulse Rate Range: 25-240Bpm 2. (7) Mobile Work Surface Period of Performance Delivery is required within 30 days after receipt of award. Place of Performance 1201 Heritage Circle, Pawnee, OK 74058