Adjustable Sprinkler Head Assembly

Project ID: 1202SC26SS2708 FederalOpportunitiesSources Sought
Overview
AgencyForest Service
Deadline06/05/26
Posted05/29/26
Estimated ValueNot Provided
Set AsideSBA
NAICS332919 - Other Metal Valve and Pipe Fitting Manufacturing
PSC4210 - Fire Fighting Equipment
LocationLakewood, CO 80225 United States
Description
Primary Latest Change

Summary

The USDA/Forest Service, Rocky Mountain Area Incident Support Cache (RMK) intends to procure an estimated number of Adjustable Sprinkler Head Assembly (NFES 0998) listed in the Deliverables and Services section for use during prescribed burns and wildfire incidents. The National Wildfire Coordinating Group (NWCG) establishes standards for fire supplies and equipment in the National Fire Equipment System (NFES) Catalog Part 1: Fire Supplies and Equipment, (PMS 449-1). National Interagency Support Caches (NISC) provide necessary equipment to field crews, wildland fire fighters, support staff, and other essential personnel for deployment to wildfire and prescribed fire incidents following NWCG standards. Adjustable Sprinkler Head Assembly NFES 0998 are new items not yet included in the NFES catalog. They will be included in Water Handling Kit 1048 along with the current non-adjustable Sprinkler Head Assembly NFES 0999 and may possibly replace NFES 0999 completely.

Deliverables and Services

The Adjustable Sprinkler Head Assembly shall contain 3 pieces: - Full or part-circle (adjustable) solid brass or bronze impact sprinkler head. - Forty-five (45) degree angle elbow body. - Brass swivel. See 1202SC26SS2708 Attachment 1 Adjustable Sprinkler Head Assembly Specifications for standards, drawings, and specifications. Also note, this requirement requires special packaging and markings. The Vendor shall be able to ship Adjustable Sprinkler Head Assembly items to the Rocky Mountain Incident Support Cache, Lakewood, CO.

Summary (Newest Update)

Background The USDA/Forest Service, Rocky Mountain Area Incident Support Cache (RMK) intends to procure an estimated number of Adjustable Sprinkler Head Assembly (NFES 0998) for use during prescribed burns and wildfire incidents. The National Wildfire Coordinating Group (NWCG) establishes standards for fire supplies and equipment in the National Fire Equipment System (NFES) Catalog Part 1: Fire Supplies and Equipment. National Interagency Support Caches (NISC) provide necessary equipment to field crews, wildland firefighters, support staff, and other essential personnel for deployment to wildfire and prescribed fire incidents following NWCG standards. The Adjustable Sprinkler Head Assembly NFES 0998 are new items not yet included in the NFES catalog and will be included in Water Handling Kit 1048, potentially replacing the current non-adjustable Sprinkler Head Assembly NFES 0999. Work Details The Adjustable Sprinkler Head Assembly shall contain 3 pieces: 1. Full or part-circle (adjustable) solid brass or bronze impact sprinkler head with stainless steel springs, spindle, and fulcrum pin; a 1/2” – 14 Male National Pipe Thread (MNPT) inlet; a removable straight bore nozzle with an orifice of 5/32” or 4mm - 24 UNF threaded; no polymer or non-metal parts except for critical bearings, bushings, washers, and spacers. 2. Forty-five (45) degree angle elbow body made from cast aluminum alloy, with a maximum overall length of 4.0 inches, inlet and outlet both being ½” NPT threaded male and female respectively. 3. Brass swivel fitting reducing from 3/4" Female Hose Thread (FHT) to 1/2" Female Pipe Thread Fitting (FNPT) with a rubber gasket. Special packaging is required: packaged in cartons of 20 units with specific dimensions and strength ratings. Period of Performance The geographic location(s) the product will be delivered to or performed at. Place of Performance Rocky Mountain Incident Support Cache, Lakewood, CO. Bidder Requirements Vendors must demonstrate capability to provide the Adjustable Sprinkler Head Assembly NFES 0998 as specified. No specific certifications or licenses are mentioned; however, adherence to NWCG standards is implied. Incumbent Analysis (see Incumbents section for more detail) The prior awards for NFES sprinkler head assemblies indicate a confirmed incumbent, with S&H Products receiving contracts 1202SC25P2701 ($288,075; 16,500 EA of NFES 0999) and 1202SC24P2704 ($240,000; 10,000 EA of NFES 0999) for the Rocky Mountain Incident Support Cache. The current requirement is for an “Adjustable Sprinkler Head Assembly” (NFES 0998) that is described as a new item potentially included in Water Handling Kit 1048 alongside the existing non-adjustable NFES 0999 and may replace it. The specified components and function are consistent with a continuation or upgrade of the same sprinkler head assembly supply line used in wildfire/prescribed burn water handling.

Contacts
Contact nameShannon Meadows
Contact emailshannon.meadows@usda.gov
Contact phoneNone