691 | Optical Coherence Tomography System w/ Table and Software

Project ID: 36C24W26Q0163 FederalOpportunitiesSynopsis Solicitation
Overview
AgencyVISN 21: Sierra Pacific Network
Deadline05/27/26
Posted05/13/26
Estimated Value$70,000 - $180,000 (AI estimate)
Set AsideNone
NAICS339112 - Surgical and Medical Instrument Manufacturing
PSC6515 - Medical And Surgical Instruments, Equipment, And Supplies
LocationDepartment of Veterans Affairs VA Greater Los Angeles Healthcare System Bakersfield, CA 93311 United States
Description
Primary Latest Change

This is a Combined Synopsis/Solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Proposals are being requested and a written solicitation will not be issued. The solicitation number is 36C24W26Q0163. This acquisition is issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, effective 03/13/2026. The associated North American Industrial Classification System Code (NAICS) for this procurement is 339112 with a small business standard of 1,000 employees. This acquisition is solicited as Unrestricted, Open Market. PLEASE READ ALL ATTACHMENTS

Summary (Newest Update)

Background The Department of Veterans Affairs, specifically the Regional Procurement Office West (RPOW), is issuing this solicitation for an Optical Coherence Tomography System (OCT) with a table and software. This acquisition aims to enhance patient care at the Bakersfield VA Clinic, which is part of the VA Greater Los Angeles Healthcare System. The OCT system is essential for diagnosing and treating eye diseases, injuries, or diminishing vision, thereby improving healthcare services provided to veterans. Work Details The requirement includes the procurement of one Optical Coherence Tomography System (OCT) with the following specifications: 1. Core technologies: cSLO, SD-OCT, Active Eye Tracking, Noise Reduction, Auto Rescan. 2. Minimum Multimodal Imaging capabilities: Retina, Glaucoma, Infrared-Reflectance (IR). 3. Light Sources: IR laser 815 nm and OCT-SLD 880 nm. 4. Standard Objective Lenses with a maximum scan field of 30° × 30° and ART up to 100 images. 5. Widefield Imaging Objective Lens with a maximum scan field of Ø 55°. 6. Ultra-Widefield Imaging Objective Lens with a maximum scan field Ø 102°. 7. OCT – Retinal imaging specifications including A-scan rate of 85 kHz to 125 kHz and axial resolution of 3.9 μm/pixel. 8. Dimensions: 25.20”D x 43.40”W x 42”H. 9. Must include a table and EMR connectivity. Period of Performance 60 days after receipt of order (ARO). Place of Performance Bakersfield VA Clinic, 900 Old River Rd., Bakersfield, CA 93311.

Contacts
Contact nameAngela Kyte
Contact emailangela.kyte@va.gov
Contact phone(210) 740-2564
Same Region Opportunities

Hot Line Fluid Warmer

Agency: VISN 22: Desert Pacific Healthcare Network

Location: California

NAICS: 339112