Description
Primary Latest Change

Elevator safety inspections for all traction and hydraulic elevators located at Central Arkansas Veterans Healthcare System (CAVHS) in Little Rock and North Little Rock, AR. The elevator maintenance contractor under contract with the CAVHS at the specific building location shall be present and assist in the inspection and testing. The elevator maintenance contractor shall provide the necessary expertise, manpower, test weights, gauges, dynamometers, etc., to perform the various inspections and tests required by code. The elevator inspector shall provide door pressure gauges, stopwatches, calipers, flashlights, and other small hand tools necessary to conduct inspections. All safety inspections shall be made in accordance with the latest revised edition of the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators, Manual A17.1, Sections X, A17.2, A17.3, A17.4, A17.5, and A18.1. The most current publication shall be used at all times.

Summary (Newest Update)

Background The Central Arkansas Veterans Healthcare System (CAVHS) is issuing this contract for elevator safety inspections for all traction and hydraulic elevators located at their facilities in Little Rock and North Little Rock, AR. The goal of this contract is to ensure the safety and compliance of the elevators with the latest standards set by the American Society of Mechanical Engineers (ASME) Safety Code for Elevators and Escalators. Work Details The contractor shall provide comprehensive elevator safety inspection services, which include: conducting semi-annual inspections, annual safety tests, and five-year load tests on electric elevators, as well as three-year pressure tests on hydraulic elevators and dumbwaiters. The contractor must supply all necessary tools, including door pressure gauges, stopwatches, calipers, flashlights, and other small hand tools. Inspections must adhere to ASME A17.1 standards and include thorough checks of all components to ensure safe operation. The contractor is responsible for providing qualified personnel certified by the Elevator Safety Division at the Arkansas Department of Labor and Licensing. Deliverables include detailed inspection reports that document findings, deficiencies, and recommendations for corrective actions. Place of Performance Central Arkansas Veterans Healthcare System (CAVHS), 2200 Fort Roots Drive, North Little Rock, AR.

Contacts
Contact nameCarmyn E Williams
Contact emailcarmyn.williams@va.gov
Contact phone(713) 799-0795
Same Region Opportunities