523A5-18-371 Building 4 Elevator Replacement VAMC Brockton

Project ID: 036C24126Q0250 FederalOpportunitiesSolicitation
Overview
AgencyVISN 1: New England Healthcare System
Deadline04/01/26
Posted02/23/26
Estimated Value<$250,000 (solicitation indicates Simplified Acquisition Procedures, which in most cases, applies to contracts expected to be less than $250K in value)
Set AsideSDVOSB
NAICS236220 - Commercial and Institutional Building Construction
PSCZ2DA - Repair Or Alteration Of Hospitals And Infirmaries
LocationBrockton, MA 02301 United States
Description
Primary Latest Change

The Building 4 Elevator Replacement will take place at Building 4 of the Brockton VA Healthcare System Campus in Brockton, MA. The project will consist of Modernization of existing elevators; (1) passenger 3 stop elevator and (1) service 3 stop elevator and associated work necessary to support project. Elevator modernization and associated work. Work includes general construction, alterations, indicators, calls and notification systems, minor site preparation for access and staging and work to support enclosed elevator machine room in existing penthouse. Necessary removal of existing structures and construction and certain other items. The work shall include all demolition and construction necessary to execute the project as defined in the construction documents and as may be implied from the intended use. Removal of regulated building materials shall be conducted in accordance with abatement procedures as per Report (attached). All electrical work necessary for the Modernization of existing elevators must be executed by a Massachusetts licensed electrical contractor. All mechanical work necessary for the Modernization of existing elevators must be executed by a Massachusetts licensed mechanical contractor. All elevators work necessary for the Modernization of existing elevators must be executed by a Massachusetts licensed Class C11 Elevator contractor. The general contractor is responsible for ensuring all technicians involved have Certified Elevator Technicians (CETs) and contractor furnished elevator inspectors possess Qualified Elevator Inspector (QEI) certifications through the ANSI National Accreditation Board and National Association of Elevator Contractors (NAEC). Complete the work within 365 calendar days from the tentative NTP of May 2026. Scope considerations include coordinating with VA Facilities staff, obtaining necessary permits, scheduling work, keeping the site clean, and complying with all applicable regulations and codes. All materials and shop drawings must be approved by the COR, and work must follow Massachusetts DLS regulations and OSHA codes. The period of performance for the project is 365 Calendar Days.

Summary (Newest Update)

Background The Building 4 Elevator Replacement project is being conducted at the Brockton VA Healthcare System Campus in Brockton, MA. The Veterans Affairs Medical Center (VAMC) aims to modernize existing elevators to enhance operational efficiency and safety within the facility. This contract encompasses the modernization of a passenger elevator and a service elevator, along with necessary supporting work. Work Details The scope of work includes: - Modernization of one passenger 3-stop elevator and one service 3-stop elevator. - General construction tasks including renovations, alterations, and installation of indicators, calls, and notification systems. - Minor site preparation for access and staging as well as support for the enclosed elevator machine room in the existing penthouse. - Demolition and construction necessary to execute the project as defined in the construction documents. - Removal of regulated building materials following abatement procedures. - All electrical work must be performed by a Massachusetts licensed electrical contractor; mechanical work by a Massachusetts licensed mechanical contractor; and elevator work by a Massachusetts licensed Class C11 Elevator contractor. - The general contractor must ensure that all technicians have Certified Elevator Technicians (CETs) certifications and that contractor-furnished elevator inspectors possess Qualified Elevator Inspector (QEI) certifications. Period of Performance The entire scope of work is to be completed within 365 calendar days from the Notice to Proceed, tentatively set for May 2026. Place of Performance Brockton VA Healthcare System Campus, 940 Belmont Street, Brockton, Massachusetts.

Contacts
Contact nameSean D Genereux
Contact emailsean.genereux@va.gov
Contact phone413-584-4040 x26924
Same Region Opportunities