Modular Helium Compression System – OEM Equipment Manufacturer Inquiry

Project ID: 80SSC026K0001 FederalOpportunitiesSpecial Notice
Overview
AgencyShared Services Center
Deadline01/16/26
Posted01/06/26
Estimated ValueNot Provided
Set AsideNone
NAICS333912 - Air and Gas Compressor Manufacturing
PSC4310 - Compressors And Vacuum Pumps
LocationStennis Space Center, MS 39529 United States
Description
Primary

Summary

Request for Information (RFI) Title: Modular Helium Compression System OEM Equipment Manufacturer Inquiry

Location

Building 3305, High Pressure Gas Facility, Stennis Space Center, MS 39529 1. Purpose This Request for Information (RFI) is issued to identify qualified original equipment manufacturers (OEMs) capable of supplying two(2) commercial off-the-shelf (COTS), modular, skid-mounted helium compression system for high-pressure helium applications. The Government is seeking equipment manufacturers only not general contractors or engineering firms who can provide the equipment only or a complete turnkey solution including surrounding infrastructure design, fabrication, delivery, installation, and commissioning of the system. The compressed helium will be routed directly into existing on-site infrastructure. The system must be compatible with standard industry transfer connections and designed to integrate seamlessly with existing facility utilities and controls. 2. System Requirements 2.1 Performance Capacity - Medium: Helium

Inlet Pressure

50-175 PSIG

Final Discharge Pressure

6000 PSIG

Max Capacity

300 SCFM

VFD Driven

2.2 Technology - Fully automated operation with remote/local control capabilities - MODBUS TCP/IP communication - Oil removal filtration system with residual oil content 2.3 Design & Footprint - Modular, skid-mounted, cabinet-enclosed configuration - Exterior operation - Sea-level installation - Operating within the following temperature ranges:

Season Average High Average Low

Winter (Dec Feb) 63 67 F 41 44 F Spring (Mar May) 73 81 F 50 70 F Summer (Jun Aug) 90 93 F 71 73 F Fall (Sep Nov) 72 88 F 47 69 F 2.4 Turnkey Scope OEM must provide (by delivery): - Fabrication and factory testing - Delivery and installation - Commissioning and activation - Operator training and documentation 2.5 Operational Features - Instrumentation for pressure, temperature, and flow monitoring - Emergency stop and alarm systems - Oil/water separators, safety valves, and ASME-certified buffer tanks - Relocation capability 3. Requested Information Interested OEMs are requested to submit the following: - Company profile, UEI, business size, socio-economic category, and relevant experience with helium compression systems - Technical specifications of the proposed system - Conceptual diagrams - Utility requirements (power, cooling water, etc.) - Estimated lead time for: - Procurement/fabrication - Delivery - Installation and commissioning - Maintenance and support offerings - References or case studies of similar systems delivered 4. Manufacturing and U.S. Presence Please include: - Country of manufacture for major system components - U.S.-based presence (e.g., offices, service teams, fabrication facilities) - Availability of U.S.-based technical support and field service personnel 5. Pricing Information Please provide the following pricing details: - Budgetary Rough Order of Magnitude (ROM) pricing - Tariff-impacted pricing: Include any applicable import duties or tariffs - Non-tariff pricing: Provide pricing assuming no tariffs or duties apply - Notes on tariff origin: Identify any components or subsystems sourced from countries subject to U.S. import tariffs

Additional RFI Information

The market research information gathered from this RFI will be used to develop and plan a potential future procurement. Based upon information submitted in response to this RFI, NASA will determine the final content of any future solicitation(s). A determination by the Government not to procure this requirement, based upon responses to this notice, is solely within the discretion of the Government. This notice should not be construed as a formal Request for Quotation (RFQ) or Proposal (RFP). Responses to this RFI are not offers and cannot be accepted by NASA to form a binding contract. This notice is not to be construed as a commitment by the Government to make a purchase, nor will the Government pay for the information solicited or be held liable for any information obtained. Submission of any information in response to this notice is completely voluntary. Comments or suggestions relevant to this requirement are welcome and may also be included in the response. Contractors are welcome to submit any additional documentation that may support their ability to comply with the Government's requirement. No solicitation exists; therefore, do not request a copy of the solicitation. Here is a complete list of acronyms found across both documents:

ASTM American Society for Testing and Materials

CE Conformit Europ enne (European Conformity)

CSA Canadian Standards Association

cULus UL Certification for Canada and the U.S. CFM Cubic Feet per Minute CTick / RCM Regulatory Compliance Mark (Australia/New Zealand) EX-WORKS Ex Works (Incoterms shipping term)

ISO International Organization for Standardization

lbs Pounds mg/m3 Milligrams per Cubic Meter

PLC Programmable Logic Controller

PSIG Pounds per Square Inch Gauge rpm Revolutions Per Minute SCFM Standard Cubic Feet per Minute

TEFC Totally Enclosed Fan-Cooled

TFT Thin-Film Transistor (display technology)

Contacts
Contact nameWill Garrett
Contact emailwill.c.garrett@nasa.gov
Contact phoneNone
Secondary contact nameJames Hibbs
Secondary contact emailjames.s.hibbs@nasa.gov
Secondary contact phoneNone
Same Region Opportunities