Door & Dock Repair - Tobyhanna Army Depot
Agency: Department of the Army
Location: Pennsylvania
NAICS: 238290
| Agency | VISN 4 |
|---|---|
| Deadline | 07/09/26 |
| Posted | 05/19/26 |
| Estimated Value | $250,000 - $650,000 (AI estimate) |
| Set Aside | SDVOSBC |
| NAICS | 236220 - Commercial and Institutional Building Construction |
| PSC | Z2DA - Repair Or Alteration Of Hospitals And Infirmaries |
| Location | Coatesville VA Medical Center Coatesville, PA 19320 United States |
Replace Flat Roof Building 57 Project Number: 542 26 109 Description: The Department of Veterans Affairs, Coatesville VA Medical Center (VAMC), intends to issue an Invitation for Bid (IFB) for Project 542 26 109, Replace Flat Roof Building 57. The work includes the full replacement of the EPDM flat roof systems on Building 57, including the southern basement entrance/exit roof. Scope includes removal and replacement of the EPDM membrane, insulation, cants, flashing, and associated roof components; correcting roof pitch to designated roof drains; repairing concrete decking; removing abandoned rooftop equipment; replacing the existing exhaust fan and damaged exhaust hood; and installing new lightning protection for affected equipment. All work shall comply with the VA Technical Information Library (TIL), Master Construction Specifications, OSHA construction safety standards, manufacturer installation requirements, and applicable federal, state, and local regulations. The period of performance is 90 days from the Notice to Proceed.
Background The Department of Veterans Affairs, Coatesville VA Medical Center (VAMC), is issuing an Invitation for Bid (IFB) for Project 542 26 109, which involves the replacement of the flat roof on Building 57. The goal of this contract is to ensure the integrity and functionality of the roofing system, which is critical for the facility's operations. Work Details The work includes a full replacement of the EPDM flat roof systems on Building 57, including the southern basement entrance/exit roof. Specific tasks include: - Removal and replacement of the EPDM membrane, insulation, cants, flashing, and associated roof components. - Correcting roof pitch to designated roof drains. - Repairing concrete decking. - Removing abandoned rooftop equipment. - Replacing the existing exhaust fan and damaged exhaust hood. - Installing new lightning protection for affected equipment. The contractor must also investigate and repair any damaged areas of the concrete deck once the EPDM roofing is removed. All work must comply with VA Technical Information Library (TIL), Master Construction Specifications, OSHA construction safety standards, manufacturer installation requirements, and applicable federal, state, and local regulations. Period of Performance The contract will be performed over a period of 90 days from the Notice to Proceed. Place of Performance Coatesville, PA
| Contact name | Javier Perez |
|---|---|
| Contact email | javier.perez3@va.gov |
| Contact phone | (856) 259-3766 |
Agency: Department of the Army
Location: Pennsylvania
NAICS: 238290
Agency: Program Contracting Activity Central
Location: Pennsylvania
NAICS: 236220
Agency: Department of the Army
Location: Pennsylvania
NAICS: 333922
Agency: NSWC Philadelphia Division
Location: Pennsylvania
NAICS: 334513