Pais FY26 Exhaust Fan Replacement

Project ID: 140P6326Q0021 FederalOpportunitiesSolicitation
Overview
AgencyNPS Midwest Region
Deadline05/27/26
Posted05/14/26
Estimated Value$5,000 - $15,000 (AI estimate)
Set AsideSBA
NAICS238220 - Plumbing, Heating, and Air-Conditioning Contractors
PSCZ2QA - Repair Or Alteration Of Restoration Of Real Property (Public Or Private)
Location820 Columbus St Rapid City, SD 57701 USA
Description
Primary Latest Change

PAIS FY26 EXHAUST FAN REPLACEMENT

Summary (Newest Update)

Background The National Park Service (NPS) is issuing this solicitation for the replacement of an existing rooftop laboratory exhaust blower fan at Padre Island National Seashore. The goal of the contract is to ensure safe operation and compliance with laboratory ventilation standards, which are critical for personnel safety and regulatory compliance. The Division of Sea Turtle Science & Recovery operates a laboratory that requires adequate ventilation for its chemical fume hood, which has been compromised due to the deterioration of the current exhaust fan. Work Details The contractor shall provide all labor, materials, and equipment necessary to safely remove and replace the rooftop exhaust blower fan serving a laboratory chemical fume hood. The installation will be supervised by park staff to adhere to park safety standards. The contractor must furnish and install a new laboratory exhaust fan suitable for chemical fume hood service, preferably a Greenheck CUE-095-VG upblast exhaust fan or an approved alternative that meets industry standards. The replacement fan must be properly sized and configured to achieve required exhaust performance according to ANSI standards. All necessary roof curbs, flashing, sealants, and hardware must be provided and installed by the contractor. Final installation must be fully weatherproof, ensuring no exposure to water damage during construction. Upon completion, the contractor shall inspect the complete fume hood exhaust system, measure and verify fume hood face velocity, adjust airflow as necessary to achieve an average face velocity of approximately 100 feet per minute in accordance with ANSI Z9.5 laboratory ventilation guidance, and perform post-installation testing and certification. A written documentation of airflow measurements, test results, and fume hood certification must be submitted to PAIS for project records. Period of Performance The contract performance period is from June 1, 2026, to September 4, 2026. Place of Performance Padre Island National Seashore, Division of Sea Turtle Science & Recovery, 20300 Park Rd 22, Corpus Christi, TX 78418.

Contacts
Contact nameKirk, Joseph
Contact emailjoseph_kirk@nps.gov
Contact phone(605) 574-0510
Same Region Opportunities

26-0077 Wood Poles

Agency: City of Sioux Falls [SD]

Location: South Dakota

NAICS: Not Provided

BMP 437-1 Outlet

Agency: City of Sioux Falls [SD]

Location: South Dakota

NAICS: Not Provided