OSQ Rack-Mounted Edge Computer Server
Agency: Global Strike Command
Location: Missouri
NAICS: 334111
| Agency | VISN 15: Heartland Network |
|---|---|
| Deadline | 05/27/26 |
| Posted | 05/13/26 |
| Estimated Value | $12,000 - $30,000 (AI estimate) |
| Set Aside | SBA |
| NAICS | 339113 - Surgical Appliance and Supplies Manufacturing |
| PSC | 6515 - Medical And Surgical Instruments, Equipment, And Supplies |
| Location | Kansas City, MO 64128 United States |
The Kansas CIty VA Medical Center is seeking to purchase TRI W-G 8ft Motorized Height and Width Parallel Bars TG1001.EC (Brand Name or Equal) for their facility. This will include delviery and installation of tha bars. No removal of exsisting bars is required. Please see attached Statement of Work for Technical Requirements. Any questions will need to be sent to kelly.malec@va.gov NLT 04/20/2026 @ 12:00 pm CST. Please see Sections E.1 - E.3 for instructions on submissions, only complete quotes received will be evaluated. All quotes shall be submitted via email to Kelly Malec at Kelly.Malec@va.gov NLT 04/27/2026 @ 03:00 PM CST. Late submissions will not be accepted.
Background The Kansas City VA Medical Center is seeking to purchase new and unused Motorized Height and Width Parallel Bars to enhance the safety, efficiency, and quality of care in their prosthetic department. This acquisition aims to address various rehabilitation needs of veterans, ensuring tailored support and better rehabilitation outcomes. Work Details The contract includes the following items: 1. **Motorized Height and Width 8ft Parallel Bars** - **Quantity**: 1 EA - **Manufacturer (Brand Name or Equal)**: Tri W-G - **Model**: TG1001.EC - **Salient Characteristics**: - Dimensions: Length 8ft, Platform Width 54”, Bar Range 21½” – 30½”, Vertical Height Adjustment 25½” – 39¾” to top of bar. - Bariatric Weight Capacity: 1000lb - UL Classified: 60601-1 - Steel Frame: 10 Gauge Steel; 1¾” High - Anodized Handrails Standard - Electrical Requirements: 115V, 6.8A, 782W Hospital Grade Plug - Non-Skid Black Matting - Warranty: Ten (10) Year Limited Warranty 2. **Delivery and Installation** - **Quantity**: 1 JB - The contractor is responsible for installation as per product specifications, providing all necessary equipment, tools, and materials for installation. Instructional manuals must be provided after installation. Period of Performance All items shall be delivered and installed no later than 45 days after receipt of order (ARO). Place of Performance Kansas City VA Medical Center, located at 4801 East Linwood Boulevard, Kansas City, MO 64128-2226.
| Contact name | Kelly Malec |
|---|---|
| Contact email | kelly.malec@va.gov |
| Contact phone | None |
Agency: Global Strike Command
Location: Missouri
NAICS: 334111
Agency: Metropolitan St. Louis Sewer District [MO]
Location: Missouri
NAICS: Not Provided
Agency: Mountain View – Birch Tree School District [MO]
Location: Missouri
NAICS: Not Provided
Agency: City of Liberty [MO]
Location: Missouri
NAICS: Not Provided