Information Systems Cyber Security and Privacy Services - Bridge
Agency: Immediate Office of the Administrator
Location: Maryland
NAICS: Not Provided
| Agency | Goddard Space Center |
|---|---|
| Deadline | 05/15/26 |
| Posted | 05/08/26 |
| Estimated Value | Not Provided |
| Set Aside | SBA |
| NAICS | 334516 - Analytical Laboratory Instrument Manufacturing |
| PSC | 6640 - Laboratory Equipment And Supplies |
| Location | Greenbelt, MD 20770 United States |
NASA/GSFC has a requirement for a Cryogen-free Dilution Refrigerator Test for Characterization of Superconducting Detectors and Devices. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.201-1 (Simplified Procedures) as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and quotations are being requested. The following are provided in the attachments:
- ADDENDUM to 52.212-1 Instructions to Offerors Commercial Products and Commercial Services. - Solicitation Provisions/Representations and Certifications - Section 3
Background NASA Goddard Space Flight Center (GSFC) has a requirement for a Cryogen-free Dilution Refrigerator Test for the characterization of superconducting detectors and devices. This project supports NASA's mission to develop low noise cryogenic detectors and detector system components, which are essential for performance characterization and calibration in science missions, particularly for quantum sensing applications. Work Details The contractor shall provide a Cryogen-free Dilution Refrigerator Testbed capable of achieving ultralow temperatures with high cooling power. Key specifications include: - Achieve base temperature < 10 milliKelvin (mK) with no heat load. - Maintain continuous temperatures < 100 mK with a 250 microwatt (uW) heat load. - Rapid duty cycle allowing cooldown and warmup within one calendar week. - Operate without liquid cryogens for cooling or precooling. - Designed for robustness with limited maintenance requirements. - System must demonstrate sufficient cooling power and provide a leak-tight environment against electromagnetic and radiation interference. Place of Performance The services will be performed at NASA Goddard Space Flight Center and the contractor's facilities.
| Contact name | Tamika Seaforth |
|---|---|
| Contact email | tamika.r.seaforth@nasa.gov |
| Contact phone | None |
| Secondary contact name | Eboni N. Washington |
| Secondary contact email | eboni.n.washington@nasa.gov |
| Secondary contact phone | None |
Agency: Immediate Office of the Administrator
Location: Maryland
NAICS: Not Provided
Agency: Goddard Space Center
Location: Maryland
NAICS: 334516
Agency: Federal Highway Administration
Location: Maryland
NAICS: 237310
Agency: ACC Aberdeen Proving Ground
Location: Maryland
NAICS: 541330