Solicitation-C-5 ELECTRICAL SOLENOIDS-SPARES BUY
Agency: Air Force Sustainment Center
Location: Georgia
NAICS: 336413
| Agency | Air Combat Command |
|---|---|
| Deadline | 05/18/26 |
| Posted | 05/08/26 |
| Estimated Value | $25,000 - $90,000 (AI estimate) |
| Set Aside | SBA |
| NAICS | 811210 - Electronic and Precision Equipment Repair and Maintenance |
| PSC | J063 - Maint/Repair/Rebuild Of Equipment- Alarm, Signal, And Security Detection Systems |
| Location | Moody AFB, GA 31699 United States |
This is a combined synopsis and solicitation for commercial service prepared in accordance with (IAW) format in Federal Acquisition Regulation (RFO) part 12, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a separate written solicitation will not be issued
Giant Voice System Maintenance
FA483026Q0027
8 May 2026
2:00PM EST on 18 May 2026
SSgt Tahj Fuller, SSgt Jonathan Andrews
SSgt Jonathan Andrews Interested vendors are advised to review the attached Combined Synopsis/Solicitation, SF1449, and Statement of Work (SOW) for complete requirement details, submission instructions, and applicable terms and conditions
Moody AFB is seeking sources capable of providing the maintenance and sustainment of Emergency Mass Notification System (EMNS) Giant Voice (GV). The work entailed will provide for properly provisioning a preventive maintenance schedule and actions to ensure the serviceability of the system. OBJECTIVES Conduct one annual Preventive Maintenance Inspections and system upgrades at Moody AFB. All visits shall be accomplished by technicians proficient in the type of work for inspecting and testing the entire EMNS system consisting of the following: - 3 base station locations and equipment:
- EMNS power supplies at each location. - Perform diagnostic testing at each siren location, which includes performing a quiet test and inspecting the condition of each siren pole and antenna. - Perform functional testing Note: Sounding of the warning sirens is a necessary part of inspection procedures, to include public address and ATHOC. Note: Moody Command Post must have previously obtained approval to sound the sirens in advance of technicians arriving on base. - Perform diagnostic tests REACT 5000 and associated computers. - Ensure latest software upgrades are included and installed on each computer throughout the year. - All EMNS poles and Sirens (Quantity 11) - Verify proper grounding at all siren sites. - Inspect interior and exterior of cabinet for corrosion. - Ensure inside of cabinet is clean and dry. - Load-test all batteries installed in siren battery cabinets to ensure they measure at least 25 volts DC at the RTU's main circuit board. - Check charger's DC voltage located on main circuit board voltage should measure approximately 30 volts DC. - Ensure all wires and circuit connections are secure and seated firmly. - Ensure speakers are free of animals and nesting materials. - Inspection of all radios installed within each siren control cabinet, its antenna and associated antenna cable, and all base station equipment. - Verify proper grounding at all sites. - Inspection of all radios installed within each siren control cabinet, its antenna and associated antenna cable, and all base station equipment. - Provide an emergency call-out within 24 hours and all non-emergency calls within 5 duty days. Routine issues are deemed less urgent, and a response within five duty days is acceptable for these cases. The vendor is expected to respond promptly to emergency requests, particularly during extreme weather conditions. For emergency issues that cannot be resolved over the phone and when the local technician is unavailable, the response time may be extended to 48-72 hours. In such cases, the Contractor shall dispatch a field service representative.
Provide test and measurement data for all work accomplished during each inspection visit. Contractor shall submit reports electronically to the 23 CS within five (5) calendar days of work completion. Reports shall be available in electronic format that is Microsoft Word, Microsoft Excel or Adobe PDF compatible.
Contractor shall begin the annual inspection with a customer meeting to review the siren system service log and overall performance of the system over the past year. After completion of the preventative maintenance inspection (PMI), the contractor shall produce the results of the PMI report on the condition of all inspected areas.
Site POC, and respective alternate(s) shall be able to read, write, speak, and understand English. Site POC or respective alternate(s) are required to be a qualified trained technician with experience working with ATI Giant Voice (GV) equipment and systems. SAFETY The Contractor shall observe all Safety, Security, Traffic and Fire regulations presently enforced at Moody Air Force Base. Contractors shall comply with the OSHA (OSHA, Public Law 91-596) and the resulting standards, OSHA Standards 29 CFR 1910 and 1926. The detailed provisions of the act for accident prevention are directly applicable to all Contractor operations. Prime Contractors are also responsible for ensuring any sub-contractors also adhere to OSHA Guidance. OSHA compliance officers can visit Contractor worksites on the installation. Responses to this Solicitation request should reference "Giant Voice System Maintenance - Moody AFB" Responses must be submitted electronically to the following e-mail addresses: jonathan.andrews.4@us.af.mil and tahj.fuller@us.af.mil. All correspondence sent via email should contain a subject line that reads Response to Moody AFB Giant Voice System Solicitation. If this subject line is not included, the e-mail may not get through e-mail filters at Moody AFB. Filters are designed to delete emails without a subject or with a suspicious subject or attachment. Attachments with files ending in .zip or .exe are not allowable and may be deleted. Ensure only .pdf, .doc, .docx, .xsls, or .xls documents are attached to your email. All other attachment types may be deleted. Direct all questions concerning this Solicitation to jonathan.andrews.4@us.af.mil and tahj.fuller@us.af.mil no later than Thursday, 14 May 2026 at 3:00 PM EST
Background Moody Air Force Base (AFB) is seeking sources capable of providing maintenance and sustainment for the Emergency Mass Notification System (EMNS) Giant Voice (GV). The goal of this contract is to ensure the serviceability of the system through a preventive maintenance schedule and actions. Work Details The contractor will conduct one annual Preventive Maintenance Inspection and system upgrades at Moody AFB. Tasks include: - Inspecting and testing the entire EMNS system at three base station locations: Command Post, Alternate Command Post, and 23 CS/SCOTR Shop. - Performing diagnostic testing at each siren location, including quiet tests and inspections of siren poles and antennas. - Conducting functional tests that include sounding warning sirens, public address systems, and ATHOC after obtaining prior approval from the Moody Command Post. - Performing diagnostic tests on REACT 5000 and associated computers, ensuring installation of the latest software upgrades throughout the year. - Inspecting all EMNS poles and sirens (11 total), verifying proper grounding, checking for corrosion, ensuring cabinets are clean and dry, load-testing batteries to ensure they measure at least 25 volts DC, checking charger voltages, securing wires and connections, ensuring speakers are free from obstructions, and inspecting radios within siren control cabinets. - Providing emergency call-out services within 24 hours for urgent issues and responding to non-emergency calls within five duty days. Routine issues will have a response time of five duty days; however, emergency requests during extreme weather may require a field service representative to be dispatched if not resolvable over the phone. Period of Performance The period of performance for this contract is from July 15, 2026 to July 14, 2027. Place of Performance The contract will be performed at Moody Air Force Base located in Georgia.
| Contact name | SSgt Tahj Fuller |
|---|---|
| Contact email | tahj.fuller@us.af.mil |
| Contact phone | (229) 257-3687 |
| Secondary contact name | SSgt Jonathan Andrews |
| Secondary contact email | jonathan.andrews.4@us.af.mil |
| Secondary contact phone | (229) 257-4772 |
Agency: Air Force Sustainment Center
Location: Georgia
NAICS: 336413
Agency: Procurement Management Branch
Location: Georgia
NAICS: 334516
Agency: Georgia National Guard
Location: Georgia
NAICS: 238220
Agency: MICC Fort Benning
Location: Georgia
NAICS: 484210