Domestic Water Booster Pump

Project ID: 36C24826Q0672 FederalOpportunitiesSources Sought
Overview
AgencyVISN 8: Sunshine Healthcare Network
Deadline05/15/26
Posted05/06/26
Estimated Value$30,000 - $70,000 (AI estimate)
Set AsideSDVOSBC
NAICS332913 - Plumbing Fixture Fitting and Trim Manufacturing
PSCJ045 - Maint/Repair/Rebuild Of Equipment- Plumbing, Heating, And Waste Disposal Equipment
LocationC.W. Bill Young VA Healthcare System Bay Pines, FL 33744 United States
Description
Primary

SUBJECT* Domestic Water Booster Pump GENERAL INFORMATION CONTRACTING OFFICE S ZIP CODE* 33744 SOLICITATION NUMBER* 36C24826Q0672 RESPONSE DATE/TIME/ZONE 05-15-2026 2:00pm EASTERN TIME, NEW YORK, USA ARCHIVE 30 DAYS AFTER THE RESPONSE DATE RECOVERY ACT FUNDS N SET-ASIDE SDVOSBC PRODUCT SERVICE CODE* J045 NAICS CODE* 332913 CONTRACTING OFFICE ADDRESS Department of Veterans Affairs Network Contracting Office 8 (NCO 8) 10,000 Bay Pines Blvd Bay Pines FL 33744 POINT OF CONTACT* Contracting Officer William Penhallegon william.penhallegon@va.gov PLACE OF PERFORMANCE ADDRESS C.W. Bill Young VA Healthcare System 10000 Bay Pines Blvd. Bay Pines FL POSTAL CODE 33744 COUNTRY USA ADDITIONAL INFORMATION AGENCY S URL URL DESCRIPTION AGENCY CONTACT S EMAIL ADDRESS EMAIL DESCRIPTION DESCRIPTION Good day, SDVOSB s, VOSB s, SB s This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue a solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SDVOSB businesses. This is not a request for bids, quotes, offers, or proposals. The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside in which case all interested parties responding shall be eligible to compete. Please direct reply in the affirmative via email if you are interested and can provide the required service/product for this requirement. Please provide your capability statement, I will accept responses for this Sources Sought until the 15th of May, 2026 at 14:00 EST, thanks. STATEMENT OF NEED GENERAL The purpose of this procurement is to furnish two (2) replacement domestic water booster pumps for Building 100 (Main Hospital) at Bay Pines VA Medical Center to restore system reliability and redundancy until a future follow-on project completes tie-in of previously installed replacement pumps in a new location. BACKGROUND Building 100 is a five-level hospital and requires adequate domestic water pressure throughout the facility. The current system has three booster pumps, but only one is functional. If the remaining pump fails, the facility will lose adequate domestic water pressure to higher floors. The requested replacement pumps are intended to bridge this reliability gap. PURPOSE This SON defines the requirements for the procurement of an Aurora pump assembly model 411 or equivalent. SCOPE The vendor shall provide and deliver two (2) complete domestic water booster pump assemblies matching the referenced equipment characteristics (or equal, if approved by the Contracting Officer Representative (COR) prior to award), suitable for use as replacement pumps in the building 100 domestic water booster system. SALIENT CHARACTERISTICS Size: 3 x 4 x 14 Configuration: Horizontal split case, BF Performance: 362 GPM at 155 feet TDH Speed: 1750 RPM Coupling: Standard Base: Steel base with drip rim Motor: 40 HP, 1750 RPM, TEFC, 460/60/3 Quantity Two (2) pumps total DELIVERABLES Two (2) complete pump assemblies meeting Section 3 requirements Manufacturer product data / cut sheets Performance curve(s) Motor data Installation and maintenance manuals Warranty documentation Packing list identifying all shipped components All items to be delivered within 90 days of purchase order processing and order placement. Deliveries shall be scheduled during working hours: Monday through Friday from 0800-1630. Product shall be delivered to Bay Pines VAMC, B110 Warehouse, 10000 Bay Pines Blvd, Bay Pines, FL 33744.

Contacts
Contact nameWilliam Penhallegon
Contact emailwilliam.penhallegon@va.gov
Contact phone727-398-6661 Ext 10082
Same Region Opportunities