Office Space Renovation Bldg 145
Agency: Department of the Army
Location: New Hampshire
NAICS: 236210
| Agency | Department of the Army |
|---|---|
| Deadline | 05/22/26 |
| Posted | 04/24/26 |
| Estimated Value | Not Provided |
| Set Aside | SBA |
| NAICS | 238120 - Structural Steel and Precast Concrete Contractors |
| PSC | 9640 - Iron And Steel Primary And Semifinished Products |
| Location | Newington, NH 03801 United States |
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Revolutionary FAR Overhaul Subpart 12.202 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is W50S8A26QA008 and is issued as a Request for Quote (RFQ), unless otherwise indicated herein. The associated North American Industrial Classification System (NAICS) code for this procurement is 238120 Structural Steel and Precast Concrete Contractors, a small business size standard of $19,000,000. This requirement is 100% set-aside for small business, and only qualified vendors may submit quotes. The solicitation will start on the date this solicitation is posted and will end on 22 May 2026, 04:00PM. Eastern Time. Free On Board (FOB) Destination shall be required to 302 Newmarket Street, Newington, NH 03801. The Government intends to award a Firm-Fixed Price (FFP) contract. The NH Air National Guard requires the following:
Provide and install three (3) C-channel steel beams under the equipment housekeeping slab by welding, as detailed in Attachment 1, to the existing Wide Flange beams. (QTY= 1 Each) Interested parties should see Instructions to Offers in the Provisions and Clauses document for details on how to submit your quotes (IAW 52.212-1) Interested parties should also see Evaluation factors in the Provisions and Clauses document for a description on how the Government intends to evaluate your quotes (IAW FAR 52.212-2) Quotes must be valid for sixty (60) days. All technical or contractual questions shall be submitted in writing via e-mail no later than 12:00 noon EST on 5 May 2026 to Casey Pridham at casey.a.pridham.mil@army.mil and Matthew Lapointe at matthew.r.lapointe.civ@army.mil. Telephone inquiries will not be accepted. If the Government responses to technical questions affect any portion of the solicitation, then an Amendment of Solicitation will be issued. The subject of your email must include your company's legal name, state the nature of your email and include the Solicitation Number W50S8A26QA008. For example, the subject of your email should be similar to the following: Quote Submission by Company XXXXX, Solicitation Number W50S8A26QA008 Company XXXXX Question Regarding Solicitation Number W50S8A26QA008. This solicitation requires registration with the System for Award Management (SAM) in order to be considered for award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. Registration must be "ACTIVE" at the time of award. See the Provisions & Clauses attachment for a complete list of provisions & clauses applicable to this solicitation
Background The NH Air National Guard is seeking to enhance the structural integrity of the mechanical mezzanine located at Building 254. This project aims to address issues arising from recent renovations where equipment was found to exceed the design capacity of the mezzanine slab. The goal of this contract is to provide and install additional structural support in the form of C-channel steel beams to mitigate stress on the existing slab. Work Details The contractor is required to provide and install three (3) C-channel steel beams under the equipment housekeeping slab by welding them to the existing Wide Flange beams. The specific requirements include: - CLIN 0001: Provide and install three (3) C-channel steel beams (C6x8.2) under the equipment housekeeping slab, as detailed in Attachment 1. - The first beam will be located directly under the center of the hydro-pneumatic tank, with two additional beams offset two feet on center to support the remaining pad. - All work must conform to AWS D1.1:2025 standards, ensuring proper fitment, surface preparation, and professional installation. Place of Performance 302 Newmarket Street, Newington, NH 03801.
| Contact name | Casey Pridham |
|---|---|
| Contact email | casey.a.pridham.mil@army.mil |
| Contact phone | (603) 715-3668 |
| Secondary contact name | Matthew Lapointe |
| Secondary contact email | matthew.r.lapointe.civ@army.mil |
| Secondary contact phone | (603) 227-1445 |
Agency: Department of the Army
Location: New Hampshire
NAICS: 236210
Agency: Drug Enforcement Administration
Location: New Hampshire
NAICS: 334516
Agency: FCI Berlin
Location: New Hampshire
NAICS: 423720
Agency: Naval Supply Systems Command
Location: New Hampshire
NAICS: 332919